London & South-East England

Retrofit Coordinator London (PAS 2035)

One qualified person responsible for the plan, the risks and the checks, from the assessment to the handover.

PAS 2030:2023 CertifiedTrustMark ApprovedOwn trained team

Is a retrofit coordinator right for your home?

  • Homeowners planning more than one measure who want one person responsible for the plan
  • Landlords and owners of flats who need a documented retrofit lodged with TrustMark
  • Projects that must follow PAS 2035 because of their funding
  • Installers who need a PAS 2035 coordinator on a customer's project
  • Architects and builders who want the retrofit risks checked alongside their own design

Retrofit Coordinator (PAS 2035): key facts

  • A retrofit coordinator is the role in PAS 2035 that manages a retrofit project from the assessment to the handover and makes sure each step follows the standard.
  • The coordinator agrees the intended outcomes, assesses the risks, writes the medium term improvement plan and checks that the design and the installation match it.
  • A coordinator is required on every project that follows PAS 2035, which includes government funded schemes and work lodged with TrustMark under PAS 2035.
  • PAS 2035:2023 has one process for every project. The risk paths A, B and C of the 2019 edition were removed.
  • Coordination is typically 5 to 10% of the cost of the works. The fee is standard rated for VAT.
  • Stay Warm has its own TrustMark registered retrofit coordinator and retrofit assessor, and holds PAS 2030:2023 as the installer.

What is a retrofit coordinator?

A retrofit coordinator is the person who holds a retrofit project together. PAS 2035, the UK specification for retrofitting homes, names five roles: the retrofit assessor, the coordinator, the designer, the installer and the evaluator. The coordinator is the one who is there from start to finish. The coordinator agrees with you what the project must achieve, reads the retrofit assessment, assesses the risks, writes the medium term improvement plan, checks that the design is suitable, inspects the work on site and makes sure the home is handed over and evaluated correctly.

The role exists because most retrofit failures happen where one job meets another. Insulation fitted with no ventilation gives condensation. A heat pump sized before the walls are insulated is too large. External wall insulation that stops short of the window reveals leaves a cold bridge. One person who is responsible for the whole plan finds these points on paper, before they cost money on site. In the older, altered homes common across London and the South-East this matters more, because few of them match the standard drawing.

Stay Warm has its own PAS 2035 retrofit coordinator and retrofit assessor, both TrustMark registered. For a homeowner or landlord, the coordinator plans the work and our own PAS 2030:2023 certified team installs the insulation, with accredited certified partners for heat pumps, solar and windows. An installer, architect or landlord who needs a coordinator for a project can also ask us to take that role. Tell us the home, the measures and whether the work will be lodged, and we will quote.

Who does the work

The coordination is done by Stay Warm's own PAS 2035 retrofit coordinator, who is TrustMark registered and works with our own retrofit assessor. Where we also install, the insulation is fitted by our own PAS 2030:2023 certified team. The coordinator can also act on a project where another TrustMark registered installer does the work.

Retrofit Coordinator (PAS 2035) cost guide

Indicative 2026 fees for London and the South-East. The coordination fee depends on the number of measures and the number of site visits, and we quote it before the project starts.

Job typeIndicative cost
Retrofit coordinationImprovement plan, design checks, site inspections, evaluation and lodgement5 – 10% of works
PAS 2035 retrofit assessmentThe survey the plan is based on, by our retrofit assessor£300 – £600
Coordinator for another firm's projectDepends on the measures, the number of homes and the visits neededQuoted per project
Several homes for one landlordSimilar homes share much of the planningQuoted per project
First conversation about the projectBy phone, with no obligationFree

VAT: 20%. Retrofit coordination is a professional service and is standard rated, so the fee carries 20% VAT. Insulation, solar, batteries and heat pumps installed under the plan are 0% VAT until 31 March 2027 (HMRC VAT Notice 708/6), and the quote shows each line.

What a retrofit coordinator does

Agrees the intended outcomes with you: comfort, bills, EPC rating, damp or all of these
Arranges and reviews the retrofit assessment of the home
Assesses the risks of the home and of the measures, and sets the checks the project needs
Writes the medium term improvement plan: each measure, the order and what can wait
Checks the design, the ventilation and the points where one measure meets another
Inspects the work, sees that handover and evaluation are done, and lodges the project with TrustMark

How retrofit coordination works

1

Outcomes and assessment

We agree what the project must achieve. Our retrofit assessor then surveys the home to PAS 2035 and records its condition, ventilation and occupancy.

2

Risks and the plan

The coordinator assesses the risks and writes the medium term improvement plan, with every measure in order and the ventilation needed with it.

3

Design check and site visits

The coordinator checks that the design suits the home, then inspects the work as it is installed to PAS 2030.

4

Handover and lodgement

The finished work is checked against the plan and evaluated. You receive the documents, and the measures are lodged with TrustMark.

A clear fee, agreed first

Tell us about the home and the work you plan. We will tell you the fee in writing before anything is booked. One point of contact from the first call to the handover.

Talk to our retrofit coordinator

Retrofit Coordinator (PAS 2035) FAQs

What does a retrofit coordinator do?
The coordinator manages a PAS 2035 project from start to finish. That means agreeing the intended outcomes, overseeing the retrofit assessment, assessing the risks, writing the medium term improvement plan, checking that the design is suitable, inspecting the installation and making sure the work is handed over, evaluated and lodged. The coordinator protects the client and the building, and does not sell a product.
When is a retrofit coordinator required?
On every project that follows PAS 2035. Government funded schemes require PAS 2035, and so does work lodged with TrustMark under PAS 2035. For work you pay for yourself, a coordinator is not a legal requirement. It is a sensible choice when you plan several measures, when the house is old or has damp, or when the work will be done in stages over some years.
What is the medium term improvement plan?
It is the plan the coordinator writes for the home. It lists every measure the home needs, the order to do them in, the ventilation that must go with them and what can be left for a later stage. Each stage is planned so that it does not have to be undone for the next one. You can use it to do the work as your budget allows.
What happened to risk paths A, B and C?
The 2019 edition of PAS 2035 put each project on risk path A, B or C, and the path set how much assessment and design it needed. PAS 2035:2023 removed the paths. Every project now follows one process, and the coordinator assesses the risks of the particular home and measures. The 2019 edition was withdrawn on 30 March 2025, so new projects follow the 2023 edition. Our guide PAS 2035 and PAS 2030 explained has more.
How much does a retrofit coordinator cost?
Coordination is typically 5 to 10% of the cost of the works. The retrofit assessment the plan is based on is typically £300 to £600. Both fees are standard rated, so VAT is 20%. We quote the fee before the project starts.
Can you act as coordinator for another installer or an architect?
Yes. Tell us the home, the measures planned, who will install them and whether the work is to be lodged with TrustMark. Lodgement needs a TrustMark registered installer for each measure. We will quote for the assessment and the coordination as a separate service.
Is the coordinator the same as the retrofit assessor or the designer?
No. The assessor records the home as it is. The designer specifies the measures. The coordinator manages the project and checks that the assessment, the design and the installation fit together. Under PAS 2035:2023 the design is the responsibility of a designer who is competent for the measures. On a whole house retrofit with us, you still deal with one project manager.

Areas we cover

We arrange a retrofit coordinator across Greater London, Surrey, Kent and Hertfordshire. See all areas we cover →

Related services

Talk to our retrofit coordinator

Leave your details and we will call you back within one working day.

We call back within one working day.