Home Upgrades · 7 min read

Government Approved Cavity Wall Insulation Installers: How to Choose One

No cavity wall insulation installer is government approved. The marks that count are PAS 2030, TrustMark and the CIGA guarantee. How to check them, what a survey must include and the red flags.

Updated 27 November 2026 · By Stay Warm Insulation

We do this work across London. Cavity Wall Insulation: mid-terrace (front and back walls): £1,000 – £2,200.

Get a free quote

There is no such thing as a government approved cavity wall insulation installer. The government does not approve, recommend or list individual firms. What you can check is three independent marks: PAS 2030 certification for cavity wall insulation, TrustMark registration and a 25 year CIGA guarantee. A good installer has all three, surveys the cavity with a borescope before quoting, and is willing to tell you not to fill the wall.

Key takeaways

  • No installer is "government approved". TrustMark is the government endorsed quality scheme, and firms register with it; that is the nearest thing.
  • PAS 2030 is the installation standard. The certificate must list cavity wall insulation as a measure, not only loft or solid wall.
  • The CIGA guarantee on a cavity fill is independent of the installer, so it still stands if the firm stops trading.
  • A real survey includes a borescope inspection of the cavity. No borescope, no quote worth having.
  • Ask for the price per m² of wall. Indicative rates are about £18 to £30 per m², at 0% VAT until 31 March 2027.
  • Walk away from doorstep offers, same day quotes without a survey, and anyone who says every wall can be filled.

Are there government approved cavity wall insulation installers?

No. People search for "government approved" or "recommended" installers because past grant schemes used that kind of wording, and because doorstep sellers still do. The government sets the rules for funded schemes but it does not vet firms one by one and it does not keep a list you can pick from.

What stands behind the phrase is a set of independent schemes. An installer who holds all of them has been checked by someone other than themselves, which is the point.

MarkWhat it isHow to check it
PAS 2030The British installation standard for energy efficiency measures. An independent certification body audits the installer against it, measure by measure.Ask for the certificate. It must be in date and must list cavity wall insulation.
TrustMarkThe government endorsed quality scheme for work in and around the home. Firms register through a scheme provider and are monitored.Search the firm name or licence number on the TrustMark website.
CIGAThe Cavity Insulation Guarantee Agency. It issues an independent guarantee on cavity fills done by its registered installers.Ask whether the installer is CIGA registered and whether the certificate will be in your name.
System approvalThe bead or wool is an approved system, and the installer is approved to fit that system.The quote should name the product and its approval certificate.
If a caller says they are "from the government scheme" or "approved by the council", ask which scheme and which certificate number. A real installer answers in one sentence. See our insulation grants guide for the schemes that still exist.

What does the CIGA guarantee cover?

The 25 year CIGA guarantee covers defects in the materials and the workmanship of a cavity fill. It is issued by CIGA, not by the installer, so it does not depend on the installing firm still trading. It belongs to the property, so a later owner can rely on it, and a buyer's solicitor will usually ask to see the certificate.

The guarantee rests on the wall having been suitable when it was filled. That is why the survey record matters as much as the certificate. Keep both with the deeds. Damage caused later by poor maintenance, such as failed pointing or a leaking gutter soaking the wall, is a different matter and is not what the guarantee is for.

If a past fill has gone wrong, read cavity wall insulation problems before you call anyone, and find the certificate first.

What should a cavity wall survey include?

The survey is where good and bad installers part company. Cavity fill is quick and cheap to install, so the pressure is always to fill. A proper survey is the only thing that stops an unsuitable wall being filled.

  • A borescope inspection. A small hole is drilled in a mortar joint and a camera goes into the cavity. It shows the width, any rubble or mortar droppings, the wall ties and any insulation already there.
  • Wall type. Brick and block cavity, not timber frame, steel frame or a system built wall. If you are not sure which you have, see cavity wall vs solid wall.
  • Exposure. Which way each wall faces, how sheltered it is, and whether there is render or cladding.
  • Condition. Pointing, cracks, render, gutters, the damp proof course and any existing damp inside.
  • Ventilation and flues. Air bricks, underfloor vents and boiler flues that must be sleeved so the fill does not block them.
  • A written result. Suitable, not suitable, or suitable after named repairs. In writing, before any price is agreed.

An honest survey sometimes ends with "do not fill this wall". Narrow cavities in 1930s houses, exposed walls and cavities full of rubble are the usual reasons. In those cases the wall can still be insulated from outside or inside; our cavity wall insulation cost guide lists when not to fill and what the alternatives cost.

What should I ask a cavity wall insulation company?

  1. Does your PAS 2030 certificate list cavity wall insulation, and can I see it?
  2. What is your TrustMark licence number?
  3. Will I receive a CIGA guarantee certificate in my name, and when?
  4. Will you inspect the cavity with a borescope before you quote?
  5. Which material do you propose, bead or mineral wool, and why for this house?
  6. What is the price per m² of wall, and what wall area have you measured?
  7. Who makes good the drill holes, and how will the mortar be matched?
  8. How are air bricks, vents and flues protected?
  9. Who deals with Building Regulations, and what paperwork do I get?
  10. If the wall turns out to be unsuitable on the day, what happens to the price?

On price, indicative London and South-East rates are about £18 to £30 per m² of wall, or £1,500 to £3,500 for a 3 bed semi, at 0% VAT until 31 March 2027. A quote far below that range usually means no real survey. A quote far above it should say why, for example scaffolding over a conservatory.

What are the warning signs of a poor installer?

  • A knock on the door or a cold call. A sale made on the doorstep often comes with no proper survey, and the survey is what decides whether the wall should be filled at all.
  • "Free under the government scheme" with no questions about your income or EPC. The remaining grants are means tested and run by councils, and the council appoints the installer.
  • A price without a visit, or a visit without a borescope.
  • "Every cavity can be filled." It cannot.
  • No named material or approval certificate on the quote.
  • A guarantee from the installer only. Ask for the independent one.
  • Pressure to sign today. A fixed written quote is still good next week.

Installer, contractor or company: who am I dealing with?

The words are used loosely. The installer is the certified firm whose technicians drill and fill the wall, and whose name is on the PAS 2030 certificate and the CIGA registration. A contractor or insulation company may install with its own team, or may survey, arrange and manage the job with a certified installer doing the fill. Both are fine. What matters is that you are told which it is, and that the certified installer is the one named on the guarantee.

Stay Warm works the second way for cavity walls. Our own team installs external wall, internal wall, loft and floor insulation under PAS 2030:2023. Cavity wall insulation is arranged and project-managed by Stay Warm and installed by accredited, certified installers who hold PAS 2030 for cavity wall insulation and TrustMark registration, with the 25 year CIGA guarantee on the fill. You have one point of contact from the survey to the certificate.

It also means we have no reason to push a fill. Where the cavity is not suitable we say so and quote external wall insulation or internal wall insulation instead. See the cavity wall insulation service page for how the survey and quote work, or our wider guide on how to choose an insulation installer for the other measures.

Frequently asked questions

Are there government approved cavity wall insulation installers?

No. The government does not approve or list individual installers. The marks to check are PAS 2030 certification for cavity wall insulation, TrustMark registration, which is the government endorsed quality scheme, and the CIGA guarantee.

How do I find a recommended cavity wall insulation installer near me?

Start with the marks, not the adverts. Check the firm on the TrustMark website, ask for a PAS 2030 certificate that lists cavity wall insulation, and ask whether the job comes with a CIGA guarantee. Then judge the survey: a recommended installer inspects the cavity with a borescope before quoting.

What is CIGA?

The Cavity Insulation Guarantee Agency. It is an independent body that issues a 25 year CIGA guarantee on cavity wall insulation fitted by its registered installers, covering defects in materials and workmanship. The guarantee stays with the property when it is sold.

Does a cavity wall insulation installer need PAS 2030?

For grant funded work, yes, together with TrustMark registration. For private work it is not a legal requirement, but it is the clearest proof that the installer has been independently audited for this measure, so we treat it as essential.

How much do cavity wall insulation installers charge?

Indicatively £18 to £30 per m² of wall in London and the South-East: £1,000 to £2,200 for a mid terrace, £1,500 to £3,500 for a 3 bed semi and £2,500 to £5,000 for a detached house. Installation is 0% VAT until 31 March 2027.

Does Stay Warm install cavity wall insulation itself?

Stay Warm surveys, arranges and project-manages cavity wall insulation, and it is installed by accredited, certified installers who hold PAS 2030 for cavity wall insulation and TrustMark registration, with a 25 year CIGA guarantee. Our own team installs external wall, internal wall, loft and floor insulation.

Want this done properly?

We survey for free and send a fixed, itemised quote within 24 hours. These are the services this guide covers, with real prices from our quote book.

  • Cavity Wall Insulation

    Arranged by us, installed by accredited, certified installers

    Mid-terrace (front and back walls): £1,000 – £2,200

  • Cavity Wall Insulation Extraction

    Arranged by us, installed by accredited, certified installers

    Extraction per m² of wall: £20 – £40 / m²

Get a free quote

Leave your details and we'll call you back within one working day to arrange a free survey.

We call back within one working day.